Honeywell alarm keypad m724012/10/2023 ![]() The Honeywell 6150 is a hardwired keypad that works with Honeywell VISTA Systems only. They are merely keypads that serve as secondary access points for controlling a security system. Neither the 6150 Keypad nor the 5828 Keypad are alarm control panels. Some users might believe that K4392V2-H M7240 is the model number for an alarm control panel. Likewise, they could take the K4392V2-H M7240 part from a 5828 and put it on a 6150. ![]() If a user wanted to, they could easily take the K4392V2-H M7240 part from a Honeywell 6150 and put it on a Honeywell 5828. Since these keypads are of similar size and have similar dimensions, Honeywell decided to use the same part for these two keypads. The K4392V2-H M7240 is nothing more than the part name of the small plastic door that covers the buttons on these keypads. ![]() ![]() The K4392V2-H M7240 is often confused for the name of either the Honeywell 6150 Keypad or the Honeywell 5828 Keypad. This plastic door is completely optional on both keypads, and it can be removed if desired. Call for service.A Honeywell K4392V2-H M7240 is the part name of the small plastic flip-down door that covers the push buttons on both the Honeywell 6150 Hardwired Keypad and the Honeywell 5828 Wireless Keypad. TELCO FAULT or CHECK 94 - The telephone line connected to the system has a problem. Long Rng Trbl or bF - This indicates a failure in your communications device. OPEN CIRCUIT or OC - The keypad is not receiving signals from the main control panel. If AC power cannot be restored and a "low system battery" message appears call for service.īusy-Standby or dI - If this message remains displayed for more than 1 minute, system is disabled. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. Call for service.ĪC LOSS or NO AC - The system is operating on battery power only due to an AC power failure. Wait a few minutes - the display should disappear.īELL FAILURE or CHECK 70 - Indicates that the wiring connection to the siren/sounder is faulted. MODEM COMM or CC - Indicates that the control is online with the Central Monitoring Station's remote computer. RF receiver, zone expander) where the xx indicates the device address. RCVR JAM or CHECK 90 - Wireless part of the system is experiencing RF interference which may impede reception from wireless sensors.ĬHECK + zone # - Indicates that a wireless zone is either not communicating properly or that the devices cover has been removed.ĪLARM 1xx FAULT 1xx CHECK 1xx or 91 - Indicates a communication problem between the control and a connected device (e.g. Either replace the battery yourself or call for service. LO BAT + zone descriptor or BAT with zone # - Indicates that there is a low battery condition in the wireless transmitter number displayed. SYSTEM LO BAT or BAT with no zone # - Indicates that a low system battery condition exists. Use the following list to identify your trouble condition:ĬOMM FAILURE or FC - Indicates that the system has attempted to communicate with the monitoring station but was unsuccessful. Now press * on your security keypad to cycle through the open zones and trouble conditions. To silence the trouble beep simply enter your 4 digit code followed by the OFF(#1) key, at the keypad. When a trouble is present the system will sound a continuous fast beeping indicator sound at the systems keypad(s) to alert you of the trouble condition. The trouble or check condition is an indication that something is not functioning properly on your Honeywell Vista security system. Have a trouble condition on your Honeywell Vista Series Security System? Use the following instructions to determine what the trouble is and find out how to stop the system from beeping.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |